Pengaruh Variasi Pencil Lead Electrode (PLE) terhadap Deteksi Ion Logam Cu²⁺ menggunakan Modifikasi MnO₂ dengan Metode Voltametri Siklik Effect of Pencil Lead Electrode (PLE) Variation on the Detection of Cu²⁺ Metal Ions Using MnO₂ Modification by Cyclic Voltammetry Method

Crossmark

Main Article Content


Abstract

This study is motivated by the limited research on the use of modified pencil lead electrodes in electrochemical detection, despite their advantages as simple, low-cost, environmentally friendly, and highly sensitive heavy metal sensors. Copper ions (Cu²⁺) are essential elements for biological functions, but in excessive amounts, they become toxic and can damage vital organs such as the liver and kidneys. The aim of this research is to develop an effective electrochemical sensor for detecting Cu²⁺ ions by optimizing the type and modification of pencil lead electrodes. Electrode modification was performed using the drop-casting method with manganese dioxide (MnO₂) on three pencil hardness grades (2B, B, and HB), with voltammogram analysis based on the resulting current and redox potential. The results indicate that the MnO₂/PLE (2B) electrode demonstrated the most optimal performance compared to the other variations. This advantage is attributed to the electrocatalytic properties of MnO₂ and the higher graphite content in 2B pencils, which enhance the electrode’s conductivity and electrochemical response. These findings confirm that MnO₂/PLE (2B) is effective for Cu²⁺ ion detection and holds potential for development as an efficient electrochemical sensor for heavy metal analysis.


Keywords: Cu²⁺ Ion; MnO₂; Pencil Electrode; Cyclic Voltammetry; Electrochemical Sensor

Downloads

Download data is not yet available.

Citation Metrics & Similar Scopus Articles

Data source Crossref
0
citations
Citation counts are source-specific and may differ because database coverage, reference matching, and update schedules are different. Counts are not added together. Crossref values represent citation links registered and matched by Crossref.
Check Secondary Documents in Scopus
Open this article in Scopus, then check the Secondary documents tab. Use Manual Citation Fallback only for counts you have verified manually.
Open in Scopus
Similar Scopus Articles
Scopus
  1. Pashentsev E.N. (2027)
    Genesis and evolution of metaverses as socio-technological realities
    Countries Studies, 5(1), 131-160
  2. Zhou X. (2027)
    Optimizing cathodic protection potential to simultaneously mitigate microbial corrosion and stress corrosion cracking of high-strength low-alloy steel in marine tidal zones
    Journal of Materials Science and Technology, 282, 314-326
  3. Lee H.G. (2027)
    Interstitial hydrogen-engineered Rh3Ag hydride nanosheets for efficient hydrogen evolution reaction
    Journal of Materials Science and Technology, 282, 83-92

Article Details

How to Cite
Permatasari, M., & Sari, T. K. (2025). Pengaruh Variasi Pencil Lead Electrode (PLE) terhadap Deteksi Ion Logam Cu²⁺ menggunakan Modifikasi MnO₂ dengan Metode Voltametri Siklik. MASALIQ, 5(4), 2062-2071. https://doi.org/10.58578/masaliq.v5i4.6859

References

Adhani, R., & Husaini. (2017). Logam Berat Sekitar Manusia. In S. Kholistunnisa (Ed.), Sustainability (Switzerland) (Vol. 11, Issue 1). Lambung Mangkurat University Press. http://scioteca.caf.com/bitstream/handle/123456789/1091/RED2017-Eng-8ene.pdf?sequence=12&isAllowed=y%0Ahttp://dx.doi.org/10.1016/j.regsciurbeco.2008.06.005%0Ahttps://www.researchgate.net/publication/305320484_SISTEM_PEMBETUNGAN_TERPUSAT_STRATEGI_MELESTARI

Bedin, K. C., Mitsuyasu, E. Y., Ronix, A., Cazetta, A. L., Pezoti, O., & Almeida, V. C. (2018). Inexpensive bismuth-film electrode supported on pencil-lead graphite for determination of Pb(II) and Cd(II) Ions by anodic stripping voltammetry. International Journal of Analytical Chemistry, 2018. https://doi.org/10.1155/2018/1473706

Bernalte, E., Foster, C. W., Brownson, D. A. C., Mosna, M., Smith, G. C., & Banks, C. E. (2016). Pencil it in: Exploring the feasibility of hand-drawn pencil electrochemical sensors and their direct comparison to screen-printed electrodes. Biosensors, 6(3). https://doi.org/10.3390/bios6030045

Cantalapiedra, A., Gismera, M. J., Procopio, J. R., & Sevilla, M. T. (2015). Electrochemical sensor based on polystyrene sulfonate-carbon nanopowders composite for Cu (II) determination. Talanta, 139, 111–116. https://doi.org/10.1016/j.talanta.2015.02.049

Coelho, D., Luiz, G. M., & Machado, S. A. S. (2021). Estimating the Electrochemically Active Area: Revisiting a Basic Concept in Electrochemistry. Journal of the Brazilian Chemical Society, 32(10), 1912–1917. https://doi.org/10.21577/0103-5053.20210080

Compton, R. G., & Banks, C. E. (2011). Understanding Voltametry. https://books.google.co.id/books?id=NM42DwAAQBAJ&printsec=frontcover&hl=id#v=onepage&q&f=false

Congur, G., & GÜL, Ü. D. (2021). Phenol monitoring in water samples using an inexpensive electrochemical sensor based on pencil electrodes modified with DTAB surfactant. Journal of Environmental Chemical Engineering, 9(5), 105804. https://doi.org/10.1016/j.jece.2021.105804

David, I. G., Popa, D. E., & Buleandra, M. (2017). Pencil graphite electrodes: A versatile tool in electroanalysis. Journal of Analytical Methods in Chemistry, 2017(Cv). https://doi.org/10.1155/2017/1905968

de Souza, R. M., Toloza, C. A. T., & Aucélio, R. Q. (2022). Fast determination of trace metals in edible oils and fats by inductively coupled plasma mass spectrometry and ultrasonic acidic extraction. Journal of Trace Elements and Minerals, 1(June), 100003. https://doi.org/10.1016/j.jtemin.2022.100003

Hanam, E. S., Awilawati, W. A., & Rismawati, E. (2024). Pengukuran Karakteristik Resistivitas Pada Bahan Grafit Pensil Tipe B, F Dan H. PASCAL (Journal of Physics and Science Learning), 8(1), 35–42. https://doi.org/10.30743/pascal.v8i1.9431

Handes, T., Permatasari, D. A. I., & Mahardika, M. P. (2021). Analisis Logam Cd, Cr, Cu dan Pb Pada Air Sumur di Sekitar Kampus Universitas Duta Bangsa Surakarta Menggunakan Metode Spektrofotometri Serapan Atom (AAS). Duta Pharma Journal, 1(1), 48–56. https://doi.org/10.47701/djp.v1i1.1192

Kawde, A., Baig, N., & Sajid, M. (2016). RSC Advances Graphite pencil electrodes as electrochemical sensors for environmental analysis : a review of features , developments , and applications. RSC Advances, 6, 91325–91340. https://doi.org/10.1039/C6RA17466C

Kementerian Kesehatan. (2023). Permenkes No. 2 Tahun 2023. Kemenkes Republik Indonesia, 55, 1–175.

Kumala Sari, T., Riga, R., & Zubir, M. (2021). Eksakta Article Pencil Lead Electrode Modified with Gold Thin Layer for Voltammetric Detection of Chromium(VI). Eksakta : Berkala Ilmiah Bidang MIPA, 22(2), 145–153. http://www.eksakta.ppj.unp.ac.id/index.php/eksakta

Ma, X., Qian, K., Kandawa-Schulz, M., Miao, W., & Wang, Y. (2020). Direct Determination of Cu2+ Based on the Electrochemical Catalytic Reaction of Fe3+/Cu2+. Electroanalysis, 32(3), 620–625. https://doi.org/10.1002/elan.201900587

Miao, L., Wang, J., & Zhang, P. (2019). Review on manganese dioxide for catalytic oxidation of airborne formaldehyde. Applied Surface Science, 466(August 2018), 441–453. https://doi.org/10.1016/j.apsusc.2018.10.031

Mokaba, P. L., Gazu, N. T., Makinita, M. L., Mthombeni, N. H., Ntola, P., & Feleni, U. (2024). Manganese Oxide Applications in Sulfonamides Electrochemical, Thermal and Optical Sensors: A Short Review. Electrocatalysis, 421–437. https://doi.org/10.1007/s12678-024-00890-x

Mourya, A., Sinha, S. K., & Mazumdar, B. (2019). Glassy carbon electrode modified with blast furnace slag for electrochemical investigation of Cu 2+ and Pb 2+ metal ions. Microchemical Journal, 147(December 2018), 707–716. https://doi.org/10.1016/j.microc.2019.03.082

Nguyen, H. T. T., Chu, N. T. H., & Le, H. T. T. (2023). Fabrication of Screen-Printed Electrodes Modified by Hydrothermal MnO2Microflowers and Carbon for Electrochemical Sensors in Copper Ions Detection. Journal of Chemistry, 2023. https://doi.org/10.1155/2023/3855430

Pour, E. S., Ebrahimi, M., & Beitollahi, H. (2022). Electrochemical Sensing of Theophylline using Modified Glassy Carbon Electrode. Chemical Methodologies, 6(7), 560–568. https://doi.org/10.22034/chemm.2022.336988.1476

Qdemat, A., Kentzinger, E., Buitenhuis, J., Rücker, U., Ganeva, M., & Brückel, T. (2020). Self assembled monolayer of silica nanoparticles with improved order by drop casting. RSC Advances, 10(31), 18339–18347. https://doi.org/10.1039/d0ra00936a

Setiawan, A., Basyiruddin, F., & Dermawan, D. (2019). Biosorpsi Logam Berat Cu(II) Menggunakan Limbah Saccharomyces Cereviseae. Jurnal Presipitasi : Media Komunikasi Dan Pengembangan Teknik Lingkungan, 16(1), 29. https://doi.org/10.14710/presipitasi.v16i1.29-35

Sousa, M. C., & Buchanan, J. W. (2000). Observational models of graphite pencil materials. Computer Graphics Forum, 19(1), 27–49. https://doi.org/10.1111/1467-8659.00386

Supriyanto, A., & Bohari. (2018). ANALISIS LOGAM Fe, Cu, Pb, DAN Zn DALAM MINYAK PELUMAS BARU DAN BEKAS MENGGUNAKAN X-RAY FLUORESCENCE. Jurnal Atomik, 03(1), 13–17.

Tsierkezos, N. G., & Ritter, U. (2014). Physics and Chemistry of Liquids : An Influence of concentration of supporting electrolyte on electrochemistry of redox systems on multi-walled carbon nanotubes. September 2014, 37–41. https://doi.org/10.1080/00319104.2012.663496

Wang, J. (2006). Analytical electrochemistry. In Analytical Chemistry (Vol. 15, Issue 1). https://doi.org/10.1016/s0165-9936(96)90116-8

Zulfa, K., & Sari, T. K. (2024). Optimization of Supporting Electrolytes for Enhanced Cu 2 + Detection Using Silver-Modified Pencil Lead Electrodes. 6(2), 155–163.