Modifikasi Ducted Fan untuk Kebutuhan Pengarah Aliran Semprotan Pupuk Cair Ducted Fan Modification for Liquid Fertilizer Spray Flow Direction Control

Crossmark

Main Article Content


Abstract

The use of agricultural drones has now experienced significant development. However, in its use it is often considered less effective because the liquid fertilizer sprayed through the nozzle tip is not on target. Then we need an additional tool in the form of a ducted fan which can increase the speed of the flow of fertilizer sprayed through the nozzle. This study uses a modification and reconstruction method of the ducted fan model that is already on the market so that it can be used as a flow guide. The modifications made are in the form of adding a cone with a size according to the hub and a height of 5 mm and a stator which is almost the same size as the fan which is around 65 mm and has the reverse direction, namely counter clock wise which functions as a flow guide. The results of the CFD research that has been carried out can be seen that the flow velocity at the outlet is 5.38394 m/s and the width of the flow which was originally 0.113791 m became 0.021235 m. Based on the results of the study it can be concluded that the fluid flow passing through the ducted fan looks smaller and directional so that it is in accordance with the purpose of the modifications that have been made and the flow speed increases so that the flow does not fly with the wind.

Keywords:
Share Article:

Citation Metrics:

Scopus

Downloads

Download data is not yet available.

Citation Metrics & Similar Scopus Articles

Data source Crossref
0
citations
Citation counts are source-specific and may differ because database coverage, reference matching, and update schedules are different. Counts are not added together. Crossref values represent citation links registered and matched by Crossref.
Check Secondary Documents in Scopus
Open this article in Scopus, then check the Secondary documents tab. Use Manual Citation Fallback only for counts you have verified manually.
Open in Scopus
Similar Scopus Articles
Scopus
  1. Wang Z. (2026)
    Wing shielding effect on tonal noise from an electric ducted fan: A numerical and experimental study
    Applied Acoustics, 254
  2. Wang Z. (2026)
    Investigation of the size effect on the aerodynamic performance and loss mechanisms of a variable-pitch ducted fan
    Aerospace Science and Technology, 178
  3. Wang S. (2026)
    Viscous-compressible design and method validation of ducted fan
    Aerospace Science and Technology, 178

Article Details

How to Cite
Afabek, R., & Nurdin, H. (2024). Modifikasi Ducted Fan untuk Kebutuhan Pengarah Aliran Semprotan Pupuk Cair. MASALIQ, 4(1), 392-399. https://doi.org/10.58578/masaliq.v4i1.2643