Verifikasi Logam Berat K (Kalium) dengan Metode Flame Spektrofotometri Serapan Atom (SSA)

Page Numbers: 229-242
Published
2023-10-28
Digital Object Identifier: 10.58578/ajstea.v1i2.2001
Save this to:
Article Metrics:
Viewed : 269 times
Downloaded : 390 times
Article can trace at:

Author Fee:
Free Publication Fees for Foreign Researchers (0.00)

Please do not hesitate to contact us if you would like to obtain more information about the submission process or if you have further questions.




  • Mutiara Pratiwi Universitas Negeri Padang
  • M Ichlas Syawal Universitas Negeri Padang

Abstract

The method verification aims to guarantee quality, method suitability and compliance with laboratory regulations. This research wa conducted to confirm and evaluate whether the test method used was suitable for its use or not. The parameters of this verification, accuracy, limit of detectin (LoD), limit of quantification (LoQ) and control chart. The standart deviaton value of the side of the tool for metal K is 0.008, so it can be sait that the Flame Atomic Absorption Spechtrophotometer tool is very good for testing metal K. The result of the linearity test show that the R2 value for K metal is 0.9993, meaning that standart is quite accurate because in industry the permitted range of regression values is 0.995-1.000. The LoD value of K metal is 0.0672 and LoQ is 0.2236. Judging from the % RCE data obtained, it shows that the concentration of the K metal series is suitable for use because it is in accordance with the tool’s capabilities, which is less than 1%. The calculation results explain that all the verification test parameters of the method used are suitable for their use.

Keywords: Verification Method; Precision; Accuracy; LoD; LoQ; Control Chart

Citation Metrics:






Downloads

Download data is not yet available.
How to Cite
Pratiwi, M., & Syawal, M. I. (2023). Verifikasi Logam Berat K (Kalium) dengan Metode Flame Spektrofotometri Serapan Atom (SSA). Asian Journal of Science, Technology, Engineering, and Art, 1(2), 229-242. https://doi.org/10.58578/ajstea.v1i2.2001

References

Greenwood, Norman N.; Earnshaw, A. (1997), Chemistry of the Elements (edisi ke-2), Oxford: Butterworth-Heinemann, ISBN 0-7506-3365-4
Harmita, H. (2004). Petunjuk Pelaksanaan Validasi Metode Dan Cara Perhitungannya. Majalah Ilmu Kefarmasian, 1(3), 117–135. https://doi.org/10.7454/psr.v1i3.3375
International Union of Pure and Applied Chemistry (2005). NOMENCLATURE OF INORGANIC CHEMISTRY IUPAC Recommendations 2005 IUPAC Periodic Table of the Elements Fm No. (2005).
Saiya, A., Gumolung, D., & Caroles, J. D. S. (2018). Analisis Residu Pestisida dalam Tomat, Cabai Rawit dan Wortel dari Beberapa Pasar Tradisional di Sulawesi Utara. Fullerene Journal of Chemistry, 3(2), 63. https://doi.org/10.37033/fjc.v3i2.40
Sukaryono, I. D., Hadinoto, S., & Fasa, L. R. (2017). Verifikasi Metode Pengujian Cemaran Logam pada Air Minum dalam Kemasan (AMDK) dengan Metode AAS-GFA. Majalan Biam, 13(1), 8–16.
Universitas Islam Indonesia. (2009, September 7). Chemistry.uii.ac.id. Retrieved from Verifikasi dan Validasi Metoda di Laboratorium: https://chemistry.uii.ac.id/verifikasi-dan-validasi-metoda-di-laboratorium/

Most read articles by the same author(s)