Crossmark

Main Article Content


Abstract

The method verification aims to guarantee quality, method suitability and compliance with laboratory regulations. This research wa conducted to confirm and evaluate whether the test method used was suitable for its use or not. The parameters of this verification, accuracy, limit of detectin (LoD), limit of quantification (LoQ) and control chart. The standart deviaton value of the side of the tool for metal K is 0.008, so it can be sait that the Flame Atomic Absorption Spechtrophotometer tool is very good for testing metal K. The result of the linearity test show that the R2 value for K metal is 0.9993, meaning that standart is quite accurate because in industry the permitted range of regression values is 0.995-1.000. The LoD value of K metal is 0.0672 and LoQ is 0.2236. Judging from the % RCE data obtained, it shows that the concentration of the K metal series is suitable for use because it is in accordance with the tool’s capabilities, which is less than 1%. The calculation results explain that all the verification test parameters of the method used are suitable for their use.

Downloads

Download data is not yet available.

Citation Metrics & Similar Scopus Articles

Data source Crossref
1
citations
Citation counts are source-specific and may differ because database coverage, reference matching, and update schedules are different. Counts are not added together. Crossref values represent citation links registered and matched by Crossref.
Check Secondary Documents in Scopus
Open this article in Scopus, then check the Secondary documents tab. Use Manual Citation Fallback only for counts you have verified manually.
Open in Scopus
Similar Scopus Articles
Scopus
  1. Qiao Y. (2027)
    Effects of CO2 jet injection on methane explosion dynamics and flame propagation in a confined pipeline
    Fuel, 430
  2. Kim K. (2027)
    Effects of wall heat loss on flame structure and near-wall thermo-chemical interactions in laminar wall-stagnating spray flames
    Fuel, 430
  3. Yang Z. (2027)
    Biomimetic interface-regulated composite coatings on flexible fabrics for microwave absorption, flame retardancy, and ultraviolet shielding
    Journal of Materials Science and Technology, 285, 107-117

Article Details

How to Cite
Pratiwi, M., & Syawal, M. I. (2023). Verifikasi Logam Berat K (Kalium) dengan Metode Flame Spektrofotometri Serapan Atom (SSA). Asian Journal of Science, Technology, Engineering, and Art, 1(2), 229-242. https://doi.org/10.58578/ajstea.v1i2.2001

References

Greenwood, Norman N.; Earnshaw, A. (1997), Chemistry of the Elements (edisi ke-2), Oxford: Butterworth-Heinemann, ISBN 0-7506-3365-4
Harmita, H. (2004). Petunjuk Pelaksanaan Validasi Metode Dan Cara Perhitungannya. Majalah Ilmu Kefarmasian, 1(3), 117–135. https://doi.org/10.7454/psr.v1i3.3375
International Union of Pure and Applied Chemistry (2005). NOMENCLATURE OF INORGANIC CHEMISTRY IUPAC Recommendations 2005 IUPAC Periodic Table of the Elements Fm No. (2005).
Saiya, A., Gumolung, D., & Caroles, J. D. S. (2018). Analisis Residu Pestisida dalam Tomat, Cabai Rawit dan Wortel dari Beberapa Pasar Tradisional di Sulawesi Utara. Fullerene Journal of Chemistry, 3(2), 63. https://doi.org/10.37033/fjc.v3i2.40
Sukaryono, I. D., Hadinoto, S., & Fasa, L. R. (2017). Verifikasi Metode Pengujian Cemaran Logam pada Air Minum dalam Kemasan (AMDK) dengan Metode AAS-GFA. Majalan Biam, 13(1), 8–16.
Universitas Islam Indonesia. (2009, September 7). Chemistry.uii.ac.id. Retrieved from Verifikasi dan Validasi Metoda di Laboratorium: https://chemistry.uii.ac.id/verifikasi-dan-validasi-metoda-di-laboratorium/